Rated scale |
|
Input |
Thermocouple |
K, J, R, S, B, E, T, N, PL-II, C(W/Re5-26) External resistance: 100 |
RTD |
Pt100, JPt100 3-wire system Allowable input lead wire resistance: 10 or less per wire |
DC current |
0-20mA DC, 4-20mA DC Input impedance: 50, Allowable input current: 50mA or less |
DC voltage |
0-10mV DC, -10-10mV DC, 0-50mV DC, 0-100mV DC, 0-1V DC Input impedance: 1M or more, Allowable input voltage: 5V DC or less Allowable signal source resistance: 2k or less |
0-5V DC, 1-5V DC, 0-10V DC Input impedance: 100k or more, Allowable input voltage: 15V DC or less Allowable signal source resistance: 100 or less |
|
Supply voltage |
100to240V AC 50/60Hz, 24V AC/DC 50/60Hz |
Allowable fluctuation range |
85to264V AC, 20to28V AC/DC |
|
|
|
General structure |
|
External dimensions |
ACD-13A, ACD-15A: 96x96x110mm (WxHxD) ACR-13A, ACR-15A: 48x96x110mm (WxHxD) |
Mounting |
Flush |
Display |
ACD-13A ACD-15A |
PV display: 24.0x11.0mm (HxW) SV/MV/TIME display: 14.0x7.0mm (HxW) |
ACR-13A ACR-15A |
PV display: 14.0x5.4mm(HxW) SV/MV/TIME display: 10.0x4.6mm (HxW) |
|
|
|
TOP
|
Standard functions |
|
Event output |
2 points of Event output
Selectable during Event output allocation by keypad -Alarm output; High limit -Alarm output; Low limit -Alarm output; High/Low limits -Alarm output; High/Low limits independent -Alarm output; High/Low limit range -Alarm output; High/Low limit range independent -Alarm output; Process high -Alarm output; Process low -Alarm output; High limit with standby -Alarm output; Low limit with standby -Alarm output; High/Low limits with standby -Alarm output; High/Low limits with standby independent -Timer output -Timer output (Control ON while timer ouput is ON) -Heater burnout alarm output (When W option is added) -Loop break alarm output -Time signal output -Output during AT -Pattern end output
|
Console communication |
By connecting the USB communication cable (CMB-001) to the Console connector of the instrument, the following operations can be conducted from the external computer using the Console software SWS-AC001M. Console communication and Serial communication cannot be used together. -Reading and setting of the SV, PID values and various set values -Reading of the PV and action status -Function change
Communication specifications -Communication protocol: Shinko protocol -Communication interface: C-MOS level -Communication method: Half-duplex communication -Synchronization method: Start-stop synchronization -Communication speed: 9600bps -Data bit: 7 -Parity: Even -Stop bit: 1 -Exclusive cable
|
Attached functions |
Sensor correction, Set value lock, Auto/Manual switching, Program control, Set value ramp, Power failure countermeasure, Self-diagnosis, Automatic cold junction temperature compensation, Burnout, Input abnormality, Warm-up indication, PV color switching, Timer, Bar graph indication |
|
|
TOP
|
Optional functions |
|
Event input (EI option) |
If this option and Serial communication (C, C5 option) are added together, Event input EVI3 and EVI4 cannot be used.
4 points of event input Selectable during Event input allocation by keypad -Set value memory function -Control ON/OFF -Direct/Reverse control action -Timer function Start/Stop -PV display; PV holding -PV display; PV peak value holding -Preset output -Auto/Manual control -Remote/Local -Program mode; RUN/STOP -Program mode; Holding/Not holding -Program mode; Advance function -Integral action holding
|
Event output (EVT3 option) |
(Only for ACD-13A, ACR-13A) If this option is added, Heating/Cooling control (DR, DS, DA option) or Insulated power output (P24 option) cannot be added together.
EVT1 to EVT3 will be added using a common terminal. Selectable by keypad during Event output allocation (the same as the standard Event output function)
|
Event output (EVT5 option) |
EVT4, EVT5 can be added. Selectable by keypad during Event output allocation (the same as the standard Event output function)
|
Heater burnout alarm (W option) |
(Only for ACD-13A, ACR-13A) Monitors heater current with CT (current transformer), and detects burnout. Rated current: Single-phase; 20A, 100A, 3-phase; 20A, 100A Setting range: 0.0 to 20.0A or 0.0 to 100.0A Setting accuracy: Within 5% of the rated current Action point: set value |
Heating/Cooling control output (Dx option)
|
(Only for ACD-13A, ACR-13A) If this option is added, Event output (EVT3 option) or Insulated power output (P24 option) cannot be added together. If this option is added, Event output EVT2 cannot be used.
An action mode is selectable by front keypad. -Air cooling: Linear characteristic -Oil cooling: 1.5th power of the linear characteristic -Water cooling: 2nd power of the linear characteristic
OUT2 output -DR: Relay contact 1a1b -DS: Non-contact voltage (for SSR drive) -DA: DC current
|
Serial communication ( C, C5 option) |
If this option and Event input (EI option) are added together, Event input EVI3 and EVI4 cannot be used.
The following operations can be carried out from the external computer. -Reading and setting of the SV, PID values and various set values -Reading of the PV and action status -Function change
Communication specifications -Communication line: C(EIA RS-232C), C5(EIA RS-485) -Communication method: Half-duplex communication -Synchronization method: Start-stop synchronization -Communication speed: 9600, 19200, 38400bps (Selectable by keypad) -Data bit: 7, 8 -Parity: Even, Odd, No parity -Stop bit: 1or 2 (Selectable by keypad) -Communication protocol: Shinko protocol, Modbus ASCII, Modbus RTU (Selectable by keypad)
Digital external setting via Shinko programmable controllers: Receives the digital set values from the Shinko programmable controllers (PC-900, PCD-33A with SVTC option). |
External setting input (Ex option) |
SV adds external analog signal to remote bias value.
Setting signal -EA(4-20): DC current 4-20mA DC -EA(0-20): DC current 0-20mA DC -EV(1-5): DC voltage 1-5V DC -EV(0-1): DC voltage 0-1V DC Input sampling 0.25sec
|
Transmission output (Tx option)
|
Converting the value (PV, SV, MV or DV transmission) to analog signal every 0.125 seconds, outputs the value in current or voltage.
Resolution: 1/12000 Output -TA: DC current 4 to 20mA DC (load resistance Max. 500) -TV: DC voltage 0 to 1V DC (load resistance Min.100k) Output accuracy: Within 0.3% of the transmission output span |
Insulated power output (P24 option) |
(Only for ACD-13A, ACR-13A) If this option is added, Event output (EVT3 option) or Heating/Cooling control (DR, DS, DA option) cannot be added together. If this option is added, Event output EVT2 cannot be used.
Output voltage: 243V DC (when load current is 30mA DC) Ripple voltage: Within 200mV DC (when load current is 30mA DC) Max load current: 30mA DC |
|
|
|
Insulation, Dielectric strength |
|
Insulation resistance
|
10M or more, at 500V DC When OUT1 and OUT2 are non-contact voltage or DC current output, OUT1 is not insulated from OUT2. |
Dielectric strength |
Between Power terminal - Ground: 1.5kV AC for 1minute Between Input terminal - Ground: 1.5kV AC for 1minute Between Input terminal - Power terminal: 1.5kV AC for 1minute |
|
|
|
Other |
|
Ambient temperature |
0 to 50 |
Ambient humidity |
35 to 85%RH (Non-condensing) |
Drip-proof/ Dust-proof |
IP66 for the front panel |
|
|
|